Sensor Filter - Light Source - Fiberoptic - Receiver - Analog - Triac - Relay - Configurable - None - Advanced

Filter
  1. DFS21IC

    Digital Fiber Optic Sensor, Infrared, 5-pin M8 Connector, Dual Channel.

  2. DFS21RC

    Digital Fiber Optic Sensor, Red, 5-pin M8 Connector, Dual Channel.

  3. DFS21R

    Digital Fiber Optic Sensor, Red, 6ft cable (1.8m), Dual Channel.

  4. DFS61I

    Digital Fiber Optic Sensor , Short-Wave Infrared, 6ft cable (1.8m)

  5. DFS31IC

    Digital Fiber Optic Sensor, High Speed, Infrared, 4-pin M8 Connector

  6. DFS31I

    Digital Fiber Optic Sensor, High Speed, Infrared, 4-wire 6ft cable (1.8m)

  7. DFS31RC

    Digital Fiber Optic Sensor, High Speed, Red, 4-pin M8 Connector

  8. DFS31R

    Digital Fiber Optic Sensor, High Speed, Red, 4-wire 6ft cable (1.8m)

  9. HSAQF1

    Analog SMARTEYE®, Near Linear High Intensity Infrared LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected.

  10. DFS11RC

    Digital Fiber Optic Sensor, Red, 4-pin M8 Connector.

  11. DFS11R

    Digital Fiber Optic Sensor, Red, 6ft cable (1.8m).

  12. DFS11IC

    Digital Fiber Optic Sensor, Infrared, 4-pin M8 Connector.

  13. DFS11I

    Digital Fiber Optic Sensor, Infrared, 6ft cable (1.8m).

  14. SAF1

    Analog SMARTEYE®, High Speed, Infrared LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected.

  15. SALF1

    Analog SMARTEYE®, High Gain, Infrared LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected. Maximum Sensing Range is depending on fiber optics.

  16. SALRF1

    Analog SMARTEYE®, High Gain, Red LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected.

  17. SAQF1

    Analog SMARTEYE®, Near Linear Infrared LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected.

  18. SARF1

    Analog SMARTEYE®, High Speed, Red LED, F1 Fiberoptic Block. 12 to 24 VDC polarity protected.

  19. TUCF-A

    U.S. EYE®, Fiberoptic Mode, contrast indictor, Infrared LED, 8ms Response Speed and On/Off Triac output.
    Opposed Range* - With Lens: 12ft; Without Lens: 2ft.
    Proximity Range* - With Lens: 4in; Without Lens: 2.5in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  20. TUF-A

    U.S. EYE®, Fiberoptic Mode, without contrast indictor, Infrared LED, 8ms Response Speed and On/Off Triac output.
    Opposed Range* - With Lens: 12ft; Without Lens: 2ft.
    Proximity Range* - With Lens: 4in; Without Lens: 2.5in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  21. UCF-A

    U.S. EYE®, Fiberoptic Mode, contrast indictor, Infrared LED, 7ms Response Speed and On/Off Relay output.
    Opposed Range* - With Lens: 12ft; Without Lens: 2ft.
    Proximity Range* - With Lens: 4in; Without Lens: 2.5in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  22. UCFR-A

    U.S. EYE®, Fiberoptic Mode, contrast indictor, Red LED, 7ms Response Speed and On/Off Relay output.
    Opposed Range* - With Lens: 6ft; Without Lens: 8in.
    Proximity Range* - With Lens: 4in; Without Lens: 1in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  23. UCT-AR

    U.S. EYE®, Beam Break Opposed Mode replacement receiver, with contrast indictor, 75ft Max Range, 7ms Response Speed and On/Off Relay output. Replacement Receiver only. See UT for the replacement light source.

  24. UF-A

    U.S. EYE®, Fiberoptic Mode, without contrast indictor, Infrared LED, 7ms Response Speed and On/Off Relay output.
    Opposed Range* - With Lens: 12ft; Without Lens: 2ft.
    Proximity Range* - With Lens: 4in; Without Lens: 2.5in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  25. UFR-A

    U.S. EYE®, Fiberoptic Mode, without contrast indictor, Red LED, 7ms Response Speed and On/Off Relay output.
    Opposed Range* - With Lens: 6ft; Without Lens: 8in.
    Proximity Range* - With Lens: 4in; Without Lens: 1in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  26. UFR-A-15

    U.S. EYE®, Fiberoptic Mode, without contrast indictor, Infrared LED, 7ms Response Speed and On/Off Relay output. Extended 15ft cable.
    Opposed Range* - With Lens: 12ft; Without Lens: 2ft.
    Proximity Range* - With Lens: 4in; Without Lens: 2.5in.
    FIBER OPTIC range tests utilized .125 in. diamter fiber bundles and UAC-15 lenses as indicated.

  27. UT-AR

    U.S. EYE®, Beam Break Opposed Mode replacement receiver, without contrast indictor, 75ft Max Range, 7ms Response Speed and On/Off Relay output. Replacement Receiver only. See UT for the replacement light source.

Filter
Set Descending Direction

27 Items

per page